Современная электроника №7/2026
СТРАНИЦЫ ИСТОРИИ 49 WWW.CTA.RU СОВРЕМЕННАЯ ЭЛЕКТРОНИКА • № 7 / 2026 p. 640, (Received October 26, 1959). Published May 1, 1960. URL: https:// journals.aps.org/pr/abstract/10.1103/ PhysRev.118.640. 6. Stern E.A., Ferrell R.A. Surface Plasma Oscillations of a Degenerate Electron Gas. Physical Review, Vol. 120, No. 1, pp. 130–136. (Received March 7, 1960), Published 1 October, 1960. URL: https://doi.org/10.1103/ PhysRev.120.130. 7. Steinmann W. Experimental Verification of Radiation of Plasma Oscillations in Thin Silver Films. Physical Review Letters. v.5, Number 10, p. 470 – Published 15 November, 1960. URL: https:// journals.aps.org/prl/abstract/10.1103/ PhysRevLett.5.470. 8. Berreman D.W. Infrared Absorption at Longitudinal Optic Frequency in Cubic Crystal Films. 130, 2193–2198 (15 June 1963). URL: https://journals.aps.org/pr/ abstract/10.1103/PhysRev.130.2193. 9. Brambring J., Raether H. Plasma Radiation from Thin Silver Foils Excited by Light. Physical Review Letters, Vol. 15, p. 882. Published 6 December 1965. URL: https://link.aps . org/doi/10.1103/PhysRevLett.15.882. 10. Steinmann W., Hofmann J., Stettmaier K. Radiation from surface plasmons. Physics Letters, Vol. 23, No. 3, pp. 234–235, 17 October, 1966. URL: https://www. sciencedirect.com/science/article/abs/ pii/003191636690881X. 11. Schreiber P., Raether H. Plasmaresonanzemission, angeregt durch Licht in Silber. Z. Naturforschg. 21 a, 2116–2117, 1966; eingeg. am 1 Dezember 1966. URL: https://www. degruyterbrill.com/document/ doi/10.1515/zna-1966-1227/html. 12. Daniels J. Energieverlustmessungen an Silber mit hoher Energieauflösung Zeitschrift für Physik.Volume 203, pages 235–249. Published: June 1967. URL: https://link.springer.com/ article/10.1007/BF01325915. 13. Kliewer K.L., Fuchs R. Collective Electronic Motion in a Metallic Slab. Physical Review, Vol. 153, Issue 2, pp. 498–512. Published 10 January, 1967. URL: https://journals.aps.org/pr/ abstract/10.1103/PhysRev.153.498. 14. Bösenberg J., Raether H. Plasma- Resonance Emission of Potassium, Excited by Light. Physical Review Letters, Vol. 18, p. 397. Published 13 March 1967. URL: https://link.aps.org/ doi/10.1103/PhysRevLett.18.397. 15. Teng Ye-Yung, Stern E. Plasma Radiation from Metal Grating Surfaces. Physical Review Letters (PRL), Vol. 19, pp. 511–514. Published 28 August, 1967. URL: https:// journals.aps.org/prl/abstract/10.1103/ PhysRevLett.19.511. 16. Zhang P. Smith-Purcell radiation driven by plasma accelerated beam. arXiv:1807.10841v2 [physics.plasm- ph] 6 August 2018. URL: https://arxiv. org/pdf/1807.10841. 17. Jasperson S.N., Schnatterly S.E. Photon-Surface-Plasmon Coupling in Thick Ag Foils Phys. Rev. v.188, p. 759. – Published 10 December, 1969. URL: https://journals.aps.org/pr/ abstract/10.1103/PhysRev.188.759. 18. Stern E.A. Plasma Radiation by Rough Surfaces. Physical Review Letters, v 19, p. 1321. Received 30 October 1967, Published 4 December, 1967. URL: https:// journals.aps.org/prl/abstract/10.1103/ PhysRevLett.19.1321. 19. Kretschmann E., Raether H. Zur Theorie der Plasmaresonanzstrahlung an rauhen Oberflächen. Zeitschrift für Naturforschung A, Vol. 22a, pp. 1623– 1625. Eingeg. am 18 August 1967, (Received 18 August 1967). URL: https://www.degruyterbrill.com/ document/doi/10.1515/zna-1967-1027/ html. 20. Wilems R.E., Ritchie R.H. Quantum Theory of the Plasma Resonance Emission Process Physical Review Letters (PRL). Vol. 19, p. 1325. – Published 4 December, 1967. URL: https://journals.aps.org/prl/ abstract/10.1103/PhysRevLett.19.1325. 21. Otto A. Excitation of Nonradiative Surface Plasma Waves in Silver by the Method of Frustrated Total Reflection. Zeitschrift für Physik, v. 216, pp. 398–410. Published: 01 August 1968. URL: https://link.springer.com/ article/10.1007/BF01391532. 22. Kretschmann E., Raether H. Notizen: Radiative Decay of Non Radiative Surface Plasmons Excited by Light, Zeitschrift für Naturforschung A, 23, 2135–2136. Received: November, 15, 1968, Published in Print: December 1, 1968. URL: https://www.degruyterbrill . com/document/doi/10.1515/zna-1968- 1247/html. 23. Economou E.N. Surface Plasmons in Thin Films. Phys. Rev. 182, 539–554 (1969). DOI: 10.1103/PhysRev.182.539. URL: https://link.aps.org/doi/10.1103/ PhysRev.182.539. 24. Kretschmann E. Die Bestimmung optischer Konstanten von Metallen durch Anregung von Oberflächenplasmaschwingungen. Z. Physik, Volume 241, pages 313– 324, 1971, Published: 01 August 1971. URL: https://link.springer.com/ article/10.1007/BF01395428. 25. Muhammad A. Butt. Surface Plasmon Resonance-Based Biodetection Systems: Principles, Progress and Applications. A Comprehensive Review. Biosensors 2025, 15(1), 35. URL: https://www.mdpi.com/2079- 6374/15/1/35. Рис. 11. Резонансная кривая в эксперименте Кречмана (1971 г.)
RkJQdWJsaXNoZXIy MTQ4NjUy