Modern Automation Technologies Professional Magazine


INDEX
# 
      2 2012

#   2/2012

Upgrade of polar crane control systems at NPP

The article discusses the features of a project to upgrade the relay-contactor control systems of operating polar cranes at NPP reactor sections. One of the distinctive features of the project, which defines the scheme-technical solutions, the choice of components and work methodology, is the location of control cabinets at hermetic zone.


# 
      1 2011

#   1/2011

Control system for the experimental multipurpose test chamber

The article describes the control system for an experimental multipurpose test chamber for developing the basic MOXfuel production processes. The challenge faced by the developers was to find a modern and reliable solution ensuring personnel safety and high accuracy of mechanism positioning.


# 
      2 2009

#   2/2009

Information and analytical system to control the liquid radioactive waste treatment complex at Kola nuclear power plant

A unique project for the automation of the liquid radioactive waste treatment complex(LRWTC) was implemented at the Kola NPP within the program of the internationalcooperation on nuclear safety. The state-of-the-art treatment technologies which haveno analogs in the world are designed to recover the liquid radioactive waste from thestorage tanks and remove the radionuclides. In accordance with the adopted FederalTarget Program, the development of the industry involves the distribution of the similarprojects within the framework of international cooperation on increase in safety andreliable operation of the nuclear power plants. Due to the LRWTC, the Kola NPP will beable, within ten years, to fully get rid of the liquid radioactive waste accumulated fromthe beginning of the plant operation.


System of the Energoatom Concern OJSC process data interchange with the automated system of the System operator: construction features

The article presents a brief technical description of the system of the EnergoatomConcern OJSC process data interchange with the automated system of the Systemoperator. It also covers the basic functions of the system, its architecture, constructionprinciples and benefits.


# 
      2 2004

#   2/2004

A microprocessor system for in-process measurement of turbogenerator's electric parameters

A microprocessor system for in-process measurement of turbogenerator's electric parameters was implemented at one of the power units at the Kolsk Nuclear Power Station. The system is based on MicroPC electronic modules and QNX real-time operating system. The article discusses the issue of the choice of hardware and software components for this project, and compares advantages and disadvantages of different solutions to this problem.


# 
      1 2003

#   1/2003

The use of an information-measurement system in the VK-50 reactor unit

This article describes the development of an information-measurement system for the VK-50 reactor unit, describing the implementation of the system onsite and analyzing the primary results of using the hardware and software that comprise the system.

(pdf 260k)
# 
      3 2002

#   3/2002

The ASUZ-03R control and security system for a PIK nuclear research reactor

This article offers a fundamentally new approach to building an integrated signaling channel for a security control system used in the hardware for a control and security system at a nuclear research reactor at the Russian Academy of Science's Petersburg Institute for Nuclear Physics.


Information and monitoring system for an SM-3 reactor unit

The authors relate the development of an information and monitoring system for an SM-3 reactor unit, describing the highlights of the system's deployment onsite and citing the results from use of the hardware and software that comprise the system.